Search results

Search for "acoustic excitation" in Full Text gives 6 result(s) in Beilstein Journal of Nanotechnology.

Reducing molecular simulation time for AFM images based on super-resolution methods

  • Zhipeng Dou,
  • Jianqiang Qian,
  • Yingzi Li,
  • Rui Lin,
  • Jianhai Wang,
  • Peng Cheng and
  • Zeyu Xu

Beilstein J. Nanotechnol. 2021, 12, 775–785, doi:10.3762/bjnano.12.61

Graphical Abstract
  • virtual atom is added above the tip apex and they are connected with a spring in the z-direction. The virtual atom is excited by a sinusoidal signal, mimicking the acoustic excitation of AM-AFM. The excited frequency is adjusted by the spring stiffness. A damping force is applied on the tip to ensure the
PDF
Album
Full Research Paper
Published 29 Jul 2021

Enhancement of X-ray emission from nanocolloidal gold suspensions under double-pulse excitation

  • Wei-Hung Hsu,
  • Frances Camille P. Masim,
  • Armandas Balčytis,
  • Hsin-Hui Huang,
  • Tetsu Yonezawa,
  • Aleksandr A. Kuchmizhak,
  • Saulius Juodkazis and
  • Koji Hatanaka

Beilstein J. Nanotechnol. 2018, 9, 2609–2617, doi:10.3762/bjnano.9.242

Graphical Abstract
  • location. The density of nanoparticles in the solution corresponds to the situation when a pressure build-up around the neighboring nanobubbles hinders their growth as observed from acoustic studies [45]. The 2 ns transient was observed in photo-acoustic excitation experiments using the same density of
PDF
Album
Full Research Paper
Published 01 Oct 2018

Material property analytical relations for the case of an AFM probe tapping a viscoelastic surface containing multiple characteristic times

  • Enrique A. López-Guerra and
  • Santiago D. Solares

Beilstein J. Nanotechnol. 2017, 8, 2230–2244, doi:10.3762/bjnano.8.223

Graphical Abstract
  • penetrating a viscoelastic solid in an intermittent-contact manner, which is a problem relevant to nanoscale spectroscopy techniques, such as tapping-mode AFM [34][35]. In standard tapping-mode AFM, a cantilever is harmonically excited either by imposing an oscillatory motion at the base (acoustic excitation
PDF
Album
Supp Info
Full Research Paper
Published 26 Oct 2017

Efficiency improvement in the cantilever photothermal excitation method using a photothermal conversion layer

  • Natsumi Inada,
  • Hitoshi Asakawa,
  • Taiki Kobayashi and
  • Takeshi Fukuma

Beilstein J. Nanotechnol. 2016, 7, 409–417, doi:10.3762/bjnano.7.36

Graphical Abstract
  • a sharp tip and a sample. Therefore, an excitation method of cantilever oscillations is an important technique in dynamic-mode AFM. Acoustic excitation is the most widely used method for cantilever excitation in dynamic-mode AFM. The method is used in many commercially available AFM systems because
PDF
Album
Supp Info
Full Research Paper
Published 10 Mar 2016

Influence of spurious resonances on the interaction force in dynamic AFM

  • Luca Costa and
  • Mario S. Rodrigues

Beilstein J. Nanotechnol. 2015, 6, 420–427, doi:10.3762/bjnano.6.42

Graphical Abstract
  • deflection, and considering both direct and acoustic excitation, we show that the cantilever behavior is insensitive to spurious resonances as long as the measured signal corresponds to the tip position, or if the excitation force is correctly considered. Since the effective excitation force may depend on
  • the presence of such spurious resonances, only the case in which the frequency is kept constant during the measurement is considered. Finally, we show the advantages that result from the use of a calibration method based on the acquisition of approach–retract curves. Keywords: acoustic excitation
  • complicated. Moreover, it has already been observed that the motion of the cantilever base due to the acoustic excitation is not negligible in situations in which the Q factor is low – a typical situation when measuring in liquids. The same holds if the cantilever is not excited close to its resonance
PDF
Album
Full Research Paper
Published 10 Feb 2015

Simultaneous current, force and dissipation measurements on the Si(111) 7×7 surface with an optimized qPlus AFM/STM technique

  • Zsolt Majzik,
  • Martin Setvín,
  • Andreas Bettac,
  • Albrecht Feltz,
  • Vladimír Cháb and
  • Pavel Jelínek

Beilstein J. Nanotechnol. 2012, 3, 249–259, doi:10.3762/bjnano.3.28

Graphical Abstract
  • “apparent dissipation”. Recently Labuda et al. [55] showed that the apparent damping can be attributed to the transfer function of the piezo-acoustic excitation system. Therefore the dissipation signal needs to be carefully analyzed because it is one of the best indicators of the instrumental artifacts. As
PDF
Album
Full Research Paper
Published 15 Mar 2012
Other Beilstein-Institut Open Science Activities